Solar panel
Solar panel
394 W Voc 40.0 V Vmp 32.8 V Imp 12.0 A
Panels per string (Series) Panels wired end to end. Each one adds its voltage to the string.
3
Number of strings (Parallel) Strings wired side by side. Each one adds its current to the array.
2
Lowest Temp
−10°C
WARNING Checked at -10 °C, not your coldest morning
Set the temperature to your area's record low so we can check cold voltage. Too much voltage can destroy a controller and start a fire.
Safety and termsMatching charge controllers
Rated for at least 140 V and 25.3 A (5% over this array).
3S2P – 6 Solar Panels
3S2P – 6 Solar Panels
132.6 V Voc
at −10°C
- Total power
- 2.36kW
- 6 panels × 394 W
- Operating voltage (Vmp)
- 98.4V
- (per string, at MPP)
- Operating current (Imp)
- 24.0A
- (2 strings × 12.0 A)
132.6 V Voc
at −10°C
- Power
- 2.36 kW
- Vmp
- 98.4 V
- Imp
- 24.0 A
Last updated: December 28, 2025